Figure 7 - Incorrect
Figure 8 - Correct
* The same flue should not be used for more than one unit or open fireplace. With
shared chimneys, each flue should reach its outlet independently and these should be
at the same level to ensure that the air circulation expels the gases;
* Brick chimneys should not be too wide, as the smoke will cool as it disperses,
reducing the draft. In case of draft problems, a revolving chimney cowl can be
installed.
5.2. Installation Location Requirements
* The unit should stand on a masonry hearth made of refractory bricks or another type
of non-combustible material;
* It is recommended for insert fires to be insulated with insulating material with a
thickness of 1,57 inches (40 mm) and a density of 154 pounds (70 kg/m3). All units
should be installed at least 15,7 inches (400 mm) from combustible materials.
* Combustible materials should not be installed close to the walls of the unit.
* The floor on which the unit will stand must be able to support a permanent load of
2,2 pounds (1kg)/cm². If the load capacity of the floor is insufficient, a solid plate can
be used to distribute the load over an area larger than the unit’s base.
* The building’s air intake grilles should not be obstructed.
Minimum 1 m above
the highest point.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Solzaima | Venus Eco 70 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Solzaima | Venus Eco 70 in the language / languages: English as an attachment in your email.

The manual is 1.65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info